Vetario T40M Intensive Care Unit (230v UK plug)

(0 reviews) Leave a review

This medical ('M') version of the S40 Intensive Care Unit has a number of additional features which makes it more flexible and better suited to veterinary applications

Price: £1,188.35 £990.29 ex In stock

Please note: We only accept BACS payments as a method of payment on orders above £1000 - please contact us for details

Key Features

  • Digital temperature control
  • Display choice of °C or °F
  • Water pan for humidity
  • Digital Humidity display
  • EX Humidity pump option
  • Temperature alarm
  • Secondary thermostat
  • Internal LED lighting
  • Nebuliser fitting
  • Oxygen compatible
  • Smooth, easy-to-clean interior
  • No vulnerable edges for animals to chew
  • Positive pressure with gentle fan ventilation
  • Twin stage filter, for removal of harmful bacteria and fungi
  • Water reservoir for increasing humidity with external top up
  • Tough, clear hinged door with secure catch
  • 3 year guarantee (subject to simple online registration)

Description

The medical ('M') version of the S40 has a number of additional features which makes it more flexible and better suited to veterinary applications:

  • Oxygen compatibility: The M version is fitted with an oxygen connector and can be safely operated with increased oxygen concentrations to aid recovery
  • Drugs can be conveniently administered to the patient using the supplied medicine reservoir connected to your nebuliser pump (suitable nebuliser pumps are available from your Vetario distributor)
  • Observation of patients is aided by a switchable internal light which safely illuminates the chamber interior
  • The control system includes audible and visual warning of temperature fluctuations outside user-defined limits. The alarm is also triggered by power failure; once power is restored it will warn that control has been lost while power was off
  • The digital display shows the humidity level as well as temperature within the chamber. The optional EX Humidity Pump can be fitted to provide fully automatic humidity control if required.

Nebuliser ampule and connector tubing supplied as standard.

Tested for Safety by BSI

The elevated oxygen levels which can be so beneficial to patients' therapy also introduces the hazard of much easier combustion. This means that the higher oxygen levels in an intensive care unit can lead to fire much more readily than in normal atmospheres. The Vetario T40M and T50M have been designed to control these risks and for additional reassurance they have been independently tested by BSI for product safety to the Animal and Medical Incubator standards.

Protected by Biomaster Antimicrobial Additives:

Hygiene in intensive care units is of vital importance, to reduce risk of infection and contamination all Vetario intensive care units incorporate Biomaster Antimicrobial Protection into the cabinets during manufacture. Biomaster Protection is embedded within the plastic itself* which prevents the growth of harmful bacteria helping to provide the optimum environment for a speedy recovery. Proven to quickly reduce bacterial growth by up to 99.99% Biomaster Protection is an effective means of reducing the risk of cross infection from MRSA, E.coli, Campylobacter, Legionella, Salmonella and many other harmful species of bacteria. Click here for more details...


Disinfecting tip:

Please make sure that disinfectant is thoroughly rinsed off plastic parts after cleaning and avoid alcohol based solutions to avoid gradual embrittlement of plastic parts.

We have come across a small number of instances of plastic parts of the Vetario Intensive Care Units and TLC brooders becoming degraded, brittle and breaking – particularly around the screws on the door hinges) due to the action of some disinfectants. To avoid this don't use disinfectants containing alcohol and take care that all traces of disinfectants or cleaning agents are rinsed away with water after cleaning, especially around the hinge screws.

This product is intended for oxygen administration by trained practitioners such as veterinary surgeons and veterinary nurses in a permanently supervised environment. Please ensure professional advice is obtained before using this product.


PLEASE NOTE: WHEN ORDERING, THIS ITEM MUST BE PAID FOR BY BACS OR PURCHASE ORDER. Please contact us on: 0345 226 0120 or sales@brinsea.co.uk for more information.

HD453A

Specification

Overall height (mm) 480

Overall width (mm) 485

Overall depth (mm) 385

Floor area (mm) 400 x 300

Effective volume (litres) 40

Power consumption (Watts) Max 160, Typical 95

Power supply 230v, 50Hz

Weight (Kg) 7.2

There are no reviews for this product yet.


Leave a review

Downloads

Explore Media

Products you may also like

Explore our innovative and effective bird breeding products

40 years of experience goes into every Brinsea product

Just wanted to send you this card as I'm so pleased with how kind you've been to me with helping me hatch my eggs from this new incubator, there's not many helpful people like you out there! The update...
Anna Cribben
Read full testimonial
I breed pure and rare poultry and have been using Brinsea Octagon 20’s for nearly 20 years. I currently have 3 Octagon Eco and 2 Octagon Advance units and find them to be very reliable machines with...
William D
Read full testimonial
Your efficient customer service and after sales care combined with the three year warranty is very reassuring and is a big factor in continuing to choose Brinsea products.  
Joe Johns
Read full testimonial
View all of our testimonials

Brinsea proudly support